fix tbeams3-core PMU charging cut-off voltage

This commit is contained in:
lewishe 2022-12-06 11:01:14 +08:00
parent 37f716d27b
commit 63d7338311

View File

@ -455,6 +455,9 @@ bool Power::axpChipInit()
// Set constant current charging current // Set constant current charging current
PMU->setChargerConstantCurr(XPOWERS_AXP192_CHG_CUR_450MA); PMU->setChargerConstantCurr(XPOWERS_AXP192_CHG_CUR_450MA);
//Set up the charging voltage
PMU->setChargeTargetVoltage(XPOWERS_AXP192_CHG_VOL_4V2);
} else if (PMU->getChipModel() == XPOWERS_AXP2101) { } else if (PMU->getChipModel() == XPOWERS_AXP2101) {
// t-beam s3 core // t-beam s3 core
@ -507,6 +510,8 @@ bool Power::axpChipInit()
//Set the constant current charging current of AXP2101, temporarily use 500mA by default //Set the constant current charging current of AXP2101, temporarily use 500mA by default
PMU->setChargerConstantCurr(XPOWERS_AXP2101_CHG_CUR_500MA); PMU->setChargerConstantCurr(XPOWERS_AXP2101_CHG_CUR_500MA);
//Set up the charging voltage
PMU->setChargeTargetVoltage(XPOWERS_AXP2101_CHG_VOL_4V2);
} }
@ -560,9 +565,6 @@ bool Power::axpChipInit()
DEBUG_MSG("=======================================================================\n"); DEBUG_MSG("=======================================================================\n");
//Set up the charging voltage, AXP2101/AXP192 4.2V gear is the same
// XPOWERS_AXP192_CHG_VOL_4V2 = XPOWERS_AXP2101_CHG_VOL_4V2
PMU->setChargeTargetVoltage(XPOWERS_AXP192_CHG_VOL_4V2);
// Set PMU shutdown voltage at 2.6V to maximize battery utilization // Set PMU shutdown voltage at 2.6V to maximize battery utilization
PMU->setSysPowerDownVoltage(2600); PMU->setSysPowerDownVoltage(2600);