mirror of
https://github.com/meshtastic/firmware.git
synced 2025-09-06 03:29:17 +00:00
messing with calibration check and default values
This commit is contained in:
parent
e1b49800ea
commit
dd6f32688b
@ -9,7 +9,7 @@ RAK12035VBSensor::RAK12035VBSensor() : TelemetrySensor(meshtastic_TelemetrySenso
|
||||
|
||||
int32_t RAK12035VBSensor::runOnce()
|
||||
{
|
||||
LOG_INFO("Init sensor: %s\n", sensorName);
|
||||
LOG_INFO("Init sensor: %s", sensorName);
|
||||
if (!hasSensor()) {
|
||||
return DEFAULT_SENSOR_MINIMUM_WAIT_TIME_BETWEEN_READS;
|
||||
}
|
||||
@ -20,14 +20,14 @@ int32_t RAK12035VBSensor::runOnce()
|
||||
// Get sensor firmware version
|
||||
uint8_t data = 0;
|
||||
sensor.get_sensor_version(&data);
|
||||
LOG_INFO("Sensor Firmware version: %i\n", data);
|
||||
LOG_INFO("Sensor Firmware version: %i", data);
|
||||
|
||||
if ( data != 0)
|
||||
{
|
||||
LOG_DEBUG("RAK12035VBSensor Init Succeed\n");
|
||||
LOG_DEBUG("RAK12035VBSensor Init Succeed");
|
||||
status = true;
|
||||
} else {
|
||||
LOG_ERROR("RAK12035VBSensor Init Failed\n");
|
||||
LOG_ERROR("RAK12035VBSensor Init Failed");
|
||||
status = false;
|
||||
}
|
||||
return initI2CSensor();
|
||||
@ -44,16 +44,26 @@ void RAK12035VBSensor::setup() {
|
||||
sensor.get_wet_cal(&hundred_val);
|
||||
delay(100);
|
||||
if(zero_val == 0 || zero_val >= hundred_val){
|
||||
LOG_COLOR_W("Dry calibration value is %d", zero_val);
|
||||
LOG_COLOR_W("Wet calibration value is %d", hundred_val);
|
||||
LOG_COLOR_W("This does not make sense. Youc can recalibrate this sensor using the calibration sketch included here: https://github.com/RAKWireless/RAK12035_SoilMoisture.");
|
||||
LOG_COLOR_W("For now, setting default calibration value for Dry Calibration: %d", default_zero_val);
|
||||
sensor.set_dry_cal(default_zero_val);
|
||||
sensor.get_dry_cal(&zero_val);
|
||||
LOG_COLOR_W("Dry calibration reset complete. New value is %d", zero_val);
|
||||
}
|
||||
if(hundred_val == 0 || hundred_val <= zero_val){
|
||||
LOG_COLOR_W("Dry calibration value is %d", zero_val);
|
||||
LOG_COLOR_W("Wet calibration value is %d", hundred_val);
|
||||
LOG_COLOR_W("This does not make sense. Youc can recalibrate this sensor using the calibration sketch included here: https://github.com/RAKWireless/RAK12035_SoilMoisture.");
|
||||
LOG_COLOR_W("For now, setting default calibration value for Wet Calibration: %d", default_hundred_val);
|
||||
sensor.set_wet_cal(default_hundred_val);
|
||||
sensor.get_wet_cal(&hundred_val);
|
||||
LOG_COLOR_W("Wet calibration reset complete. New value is %d", hundred_val);
|
||||
}
|
||||
delay(100);
|
||||
LOG_INFO("Dry calibration value is %d\n", zero_val);
|
||||
LOG_INFO("Wet calibration value is %d\n", hundred_val);
|
||||
LOG_INFO("Dry calibration value is %d", zero_val);
|
||||
LOG_INFO("Wet calibration value is %d", hundred_val);
|
||||
}
|
||||
|
||||
bool RAK12035VBSensor::getMetrics(meshtastic_Telemetry *measurement)
|
||||
|
Loading…
Reference in New Issue
Block a user