Commit Graph

7 Commits

Author SHA1 Message Date
Tom Fifield
35e1c401e2
PMSA0031 sensors require ~3secs before coming up on I2C (#4743)
* PMSA0031 sensors require ~3secs before coming up on I2C

As reported by @MALAONE1 and debugged by @shodan8192 , PMSA0031s
on a RAK4631 take 3 seconds before they can become detectable on I2c.

Add a delay(4000) before I2C scan if the air quality sensor pin
is defined.

Fixes https://github.com/meshtastic/firmware/issues/3690

* Remove 4 second wait and rescan during air quality init for the sensor

* works without but this triggers my OCD

---------

Co-authored-by: Thomas Göttgens <tgoettgens@gmail.com>
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
2024-09-18 10:12:49 -05:00
Ben Meadors
c5d747cd3e
Scale default intervals based for *online* mesh size past 40 nodes (#4277)
* Add congestion scaling coefficient

* Added active mesh sized based interval scaling

* Moved back to bottom

* Format

* Add observers and use correct number of online nodes
2024-07-13 05:59:19 -05:00
GUVWAF
8078e03f5f
Implement replies for all telemetry types based on variant tag (#4164)
* Implement replies for all telemetry types based on variant tag

* Remove check for `ignoreRequest`: modules can set this, don't need to check

---------

Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
2024-06-23 07:13:59 -05:00
Oliver Seiler
077ca5919a MESHTASTIC_EXCLUDE_ENVIRONMENTAL_SENSOR refinements 2024-05-03 14:15:13 +12:00
Oliver Seiler
be0e882be1 exclude sensors when MESHTASTIC_EXCLUDE_ENVIRONMENTAL_SENSOR set 2024-05-03 14:15:13 +12:00
Ben Meadors
1748db3160 Init struct 2023-02-04 13:35:02 -06:00
Ben Meadors
d83a0b1818 Initial air quality telemetry feature 2023-02-04 13:07:14 -06:00