Compare commits

...

2 Commits

Author SHA1 Message Date
Tom Fifield
23b8baffb4
Merge c6db0cc9da into b5a8e8f51b 2025-07-28 20:30:33 -03:00
Tom Fifield
c6db0cc9da
Fix device-install.bat baud rate
As reported by @gruberaaron , work to improve the 1200bps reset for
esptool caused all runs of device-install.bat to use 1200bps as
the baud rate.

This change removes the general SET "ESPTOOL_BAUD=1200" that was causing
the issues and places the baud settings for reset mode inside the conditional.

Fixes https://github.com/meshtastic/firmware/issues/7172
2025-07-28 18:31:51 +10:00

View File

@ -100,7 +100,6 @@ IF NOT "!FILENAME:update=!"=="!FILENAME!" (
)
:skip-filename
SET "ESPTOOL_BAUD=1200"
CALL :LOG_MESSAGE DEBUG "Determine the correct esptool command to use..."
IF NOT "__%PYTHON%__"=="____" (
@ -142,7 +141,7 @@ CALL :LOG_MESSAGE INFO "Using esptool baud: !ESPTOOL_BAUD!."
IF %BPS_RESET% EQU 1 (
@REM Attempt to change mode via 1200bps Reset.
CALL :RUN_ESPTOOL !ESPTOOL_BAUD! --after no_reset read_flash_status
CALL :RUN_ESPTOOL 1200 --after no_reset read_flash_status
GOTO eof
)